Protection Philosophy &
Schematics

Define how protection should operate and document the interfaces that support it.

A clear engineering basis for new installations and system changes.

From principles to engineering documentation

Protection Principles

Define asset requirements, protection functions and zones.

Tripping & Interlocking

Document operating relationships and control requirements.

CT/VT & Interfaces

Identify measurement and equipment interface requirements.

Control Schematics

Develop and review protection and control drawings.

Typical deliverables

  • Protection philosophy
  • Tripping matrix
  • Control schematics
  • Interface schedules

Information we review

  • Network configuration
  • Client specifications
  • Equipment details
  • Existing drawings

Document scope follows the agreed design basis.

In detail: what the work covers

Protection Philosophy & Scheme Development

A protection philosophy is the document every later decision refers back to. We prepare it early enough to shape procurement and detailed design, and clearly enough that vendors, EPC contractors and your own operations team read it the same way.

What this covers

  • Protection principles — which functions apply to each equipment class and voltage level, and why.
  • Zone definition — overlapping protected zones with no unprotected gaps between them.
  • Redundancy strategy — main and backup arrangements, duplicated supplies, and breaker failure coverage.
  • Coordination criteria — grading margins, clearance time targets, and the fault cases the design must handle.
  • Architecture — hardwired versus IEC 61850 station bus, and where each is appropriate for the site.
  • Instrument transformer and tripping requirements — CT/VT classes, trip circuit supervision, and DC supply arrangements.

Standards and references

Philosophy documents are written to align with IEC 60255, IEC 61850, the IEEE C37 series and IEC 61936-1, together with the client specification and applicable grid code.

Protection & Control Schematic Development

We develop and revise protection and control schematics for new installations, relay replacements and existing-system modifications. Drawings are prepared around the agreed protection philosophy, selected equipment and required operating sequences.

Scope

  • CT and VT secondary circuits.
  • Relay measurement and auxiliary supply connections.
  • Trip and close circuits.
  • Interlocking, permissive and blocking circuits.
  • Alarms and indications.
  • Relay, PLC and SCADA interfaces.
  • Terminal and connection schedules where included.

Establish a clear protection basis for your project.